Environmental Operating Conditions
C9010P:
Max. operating specifications:
Operating temperature: 32° to 113°F (0° to 45°C)
Operating humidity: 5 to 85% (RH), noncondensing
Operating altitude: 0ft to 10,000ft above sea level
Max. non-operating specifications:
Storage temperature: –40° to 158°F (–40° to 70°C)
Storage humidity: 5 to 95% (RH), non-condensing
C1048P:
Max. operating specifications:
Operating temperature: 32° to 113°F (0° to 45°C)
Operating humidity: 5 to 95% (RH), noncondensing
Operating altitude: 0ft to 10,000ft above sea level
Max. non-operating specifications:
Storage temperature: –40° to 149°F (–40° to 65°C)
Storage humidity: 5 to 95% (RH), non-condensing
PoE/PoE+ Power Budget: 850W using integrated
power supply. 1,700W when used in conjunction with MPS1000
Hardware
C9010:
Up to 240 line-rate1 1/10GBASE-T ports
Up to 248 line-rate1 1/10GbE SFP+ ports
Up to 60 line-rate1 40GbE QSFP+ ports
3 fan modules
4 2,900W power supplies
Up to 2 RPMs
1 RJ45 console/management port with RS232 signaling and 1 USB-B port (per RPM)
Size:
8 RU, 13.9”h x 17.4” w x 18.0” d (35.26 cm h x 44.20 cm w x 45.70 cm d)
Weight:
55.4 lbs (25.2 kg) empty, 151.3 to 165.3 lbs (68.8 to 75.1 kg) fully loaded, depending on line cards installed
C1048P:
48 10/100/1000BASE-T RJ45 PoE+
2 integrated SFP+ uplink ports
2 integrated 21Gbps stack ports
1 RJ45 Console/management port with RS232 signaling
1 USB-A Port
Size: 1 RU, 1.7”h x 17.3” w x 10.1” d (4.4 cm h x 44.0 cm w x 38.7 cm d)
Weight: 15.0 lbs (6.8 kg)
Port Attributes
Up to 60 40GbE QSFP+ ports
Up to 248 10GbE ports (240 SFP+ or 10GBASE-T ports plus eight SFP+ ports on two RPMs)
Support for 2,000 virtual ports (via rapid access nodes), and concurrent support for traditional Ethernet switches/devices
C9010 network director:
10 slot, includes 1x RPM, 1x AC PSU, 3x Fan
Modules:
C9010 Modular Switch, 10 slot, includes 1x RPM, 1x AC PSU, 3x Fan Modules, TAA
Redundant RPM:
C9000 RPM 2.56T, Redundant RPM
Line cards:
C9000 24-port 10GbE 10GBASE-T Line Card
C9000 24-port 10GbE SFP+ Line Card
C9000 6-port 40GbE QSFP+ Line Card
Redundant power supplies: C9000 2,900W Power Supply
Fans:
C9000 Hot Swappable Fan Module
C1048P rapid access node:
48x 10/100/1000BASE-T PoE+ ports, 2x SFP+ ports, 2x stacking ports, 1 integrated 1000W power supply (requires C15 plug) |
Performance
MAC addresses: 160K
IPv4 routes: 128K in scaled mode (16K in default mode)
IPv6 routes: 32K (shared CAM space with IPv4)
RPM switch fabric capacity: 2.56Tbps (full-duplex), 1.28Tbps (half-duplex)
RPM throughput: 1,462 Mpps
Line Card switch fabric capacity: 1.44Tbps (fullduplex), 720Gbps (half-duplex)
Line Card throughput: 714 Mpps
Link aggregation: 16 links per group, 128 groups per stack
Queues per port: 8 queues
Layer 2 VLANs: 4K
MSTP : 64 instances
VRF-lite: 32 instances (64 in future release)
Line-rate Layer 2 switching: all protocols, including IPv4 and IPv6
Line-rate Layer 3 routing: IPv4 and IPv6
IPv4 host table size 32K
IPv6 host table size 16K
IPv4 Multicast table size 4K
LAG load balancing: based on Layer 2, IPv4 or IPv6 headers
Power
Nominal Input Voltage: 100/120 VAC 50/60 Hz and 200/240 VAC 50/60 Hz
Max input current per power supply @ 1,450W (100/120V): 16A at 100V, 14A at 120V
Max input current per power supply @ 2,900W (200/240V): 16A at 200V, 14A at 240V
Max system power input (using 4 power supplies): 2,950 VA
Max. power consumption: 2,950W
Max. thermal output: 10,066 BTU/hr
Typ. power consumption: 1410-2400 Watts fully loaded, depending on line cards installed
Safety
UL/CSA 60950-1, Second Edition
EN 60950-1, Second Edition
IEC 60950-1, Second Edition Including All
National Deviations and Group Differences
EN 60825-1 Safety of Laser Products
Part 1: Equipment Classification Requirements and User’s Guide
EN 60825-2 Safety of Laser Products
Part 2: Safety of Optical Fibre Communication Systems
FDA Regulation 21 CFR 1040.10 and 1040.11
Emissions
Australia/New Zealand: AS/NZS CISPR 22: Class A
Canada: ICES-003, Issue-4, Class A
Europe: EN 55022: (CISPR 22:), Class A
Japan: VCCI Class A
USA: FCC CFR 47 Part 15, Subpart B: Class A
Immunity
EN 300 386 for Network Equipment
EN 55024
EN 61000-3-2: Harmonic Current Emissions
EN 61000-3-3: Voltage Fluctuations and Flicker
EN 61000-4-2: ESD
EN 61000-4-3: Radiated Immunity
EN 61000-4-4: EFT
EN 61000-4-5: Surge
EN 61000-4-6: Low Frequency Conducted Immunity
RoHS
All C Series components are EU RoHS compliant.
Certifications
Available with US Trade Agreements Act (TAA) compliance
USGv6 Host and Router Certified on Dell Networking OS 9.5 and greater*
IPv6 Ready for both Host and Router*
UCR DoD APL (core and distribution ALSAN switch)*
*USGv6, IPv6 Ready, and UC APL certifications contingent upon successful test completion[DS1]
|